Page 1
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
UNVENTED
ROOM HEATER
MODELS
SR-6-3 SR-10-3
SR-18-3 SR-30-3
SR-30 SHOWN
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
This is an unvented gas-red heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation
air must be provided. Refer to page 6.
WARNING: If not installed, operated and maintained
in accordance with the manufacturers instructions,
this product could expose you to substances in fuel
or from fuel combustion which can cause death or
serious illness.
WATER VAPOR: A BY-PRODUCT OF UNVENTED
ROOM HEATERS
Water vapor is a by-product of gas combustion.
An unvented room heater produces approximately
one (1) ounce (30ml) of water for every 1,000 BTU’s
(.3KW’s) of gas input per hour. Refer to page 6.
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
re department.
Installation and service must be performed by a
qualied installer, service agency or the gas sup-
plier.
WARNING: If the information in these instructions
are not followed exactly, a re or explosion may
result causing property damage, personal injury or
loss of life.
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - OWNER’S MANUAL

Page 1INSTALLATION INSTRUCTIONSANDOWNER’S MANUALUNVENTEDROOM HEATERMODELSSR-6-3 SR-10-3SR-18-3 SR-30-3SR-30 SHOWNThis appliance may be installed

Page 2 - TABLE OF CONTENTS

16942-9-0314Page 10When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.Left side 8

Page 3 - IMPORTANT SAFETY INFORMATION

16942-9-0314 Page 11On Solid Wall 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely

Page 4 - LP-GAS WARNING ODOR

16942-9-0314Page 121. Align clearance holes on oor stand with screw holes on bottom of heater, as shown in Figure 14.2. Attach oor stand to heater w

Page 5 - SPECIFICATIONS

16942-9-0314 Page 13FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a re or explosion may result causin

Page 6 - WARNING

16942-9-0314Page 14SR-6 Main Burner Flame (Figure 15)The main burner ame will have a red-orange glow over the sur-face of the ceramic plaque. The red

Page 7 - GAS SUPPLY

16942-9-0314 Page 15The correct ame will be blue and will extend beyond the thermocouple. The ame will surround the thermocouple just belo

Page 8 - SR-10 CLEARANCES

16942-9-0314Page 16Removing Pilot/Thermocouple From Main Burner AssemblyAttention: The thermocouple CAN NOT be replaced as an individual item. You mus

Page 9 - SR-18 CLEARANCES

16942-9-0314 Page 171. Spark electrode does not produce spark.a. Spark electrode broken - replace.b. Ignitor wire may not be attached to spark elec

Page 10 - WALL MOUNT INSTALLATION

16942-9-0314Page 18SR-6Index No.Part No.Description1 13344 CASING SIDE ASSEMBLY – LEFT2 R-2313 PIEZO IGNITOR3 R-2328 CONTROL KNOB4 SR-036 CONTROL ROD5

Page 11

16942-9-0314 Page 19USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.PARTS LISTSR-18 INDEX NO. PART NO.

Page 12 - Figure 14

16942-9-0314Page 2Important Safety Information ... 3Safety Information for Users of L

Page 13 - TO TURN OFF GAS TO APPLIANCE

16942-9-0314Page 20SR-6 PARTS VIEW

Page 14 - Figure 16

16942-9-0314 Page 21SR-10 PARTS VIEW

Page 15 - MAIN BURNER OPERATION

16942-9-0314Page 22SR-18 PARTS VIEW

Page 16 - APPLIANCE MAINTENANCE

16942-9-0314 Page 23SR-30 PARTS VIEW

Page 17 - TROUBLESHOOTING

16942-9-0314Page 24INSTALLING OPTIONAL BLOWER SRB-18 OR SRB-30If heater is installed onto the wall, in order to install the optional blower, the heate

Page 18 - PARTS LIST

16942-9-0314 Page 25Blower WheelThe blower wheel will collect lint and could require periodic cleaning. If the air output decreases or the noise level

Page 19

16942-9-0314Page 26PARTS LISTINDEX NO.PART NO.DESCRIPTION1 R-2396 BLOWER (INCLUDES MOTOR, FAN, AND FAN HOUSING)2 R-2522 ON/OFF SWITCH3 R-2395 WIRE ASS

Page 20 - SR-6 PARTS VIEW

16942-9-0314 Page 27To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provid

Page 21 - SR-10 PARTS VIEW

16942-9-0314Page 28EMPIREEMPIREComfort SystemsEmpire Comfort Systems Inc.918 Freeburg Ave. Belleville, IL 62220If you have a general question about o

Page 22 - SR-18 PARTS VIEW

16942-9-0314 Page 1INSTRUCCIONES DE INSTALACIÓNYMANUAL DEL PROPIETARIOCALENTADOR DE GAS PARA HABITACIONESMODELOS SR-6-3 SR-10-3 SR-18-3 SR-30-3ADVER

Page 23 - SR-30 PARTS VIEW

16942-9-0314 Page 3DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a hazardo

Page 24 - SRB-18 and SRB-30

16942-3-0910Page 2SECCIÓN PÁGINAImportante Información de Securidad ... 3Información de Secu

Page 25

16942-3-0910 Page 3• Un calentador de habitaciones sin ventilación externa que tenga una capacidad mayor de 6,000 Btu por hora no debe instalarse en

Page 26

16942-3-0910Page 4Gas propano (LP-GAS) es un gas inamable el cual puede causar fuegos y explosiones. En su estado natural , el propano (LP)

Page 27 - MASTER PARTS DISTRIBUTOR LIST

16942-3-0910 Page 5Instalaciones en Pozos de GasAlgunas empresas de gas natural usan gas de pozos. Esto puede afectar la capacidad de Btu o Kcal del a

Page 28 - Comfort Systems

16942-3-0910Page 6El vapor de agua es un subproducto de la combustión de gas. Un calentador de habitación sin ventilación externa produce una (1) onz

Page 29 - MANUAL DEL PROPIETARIO

16942-3-0910 Page 7La línea de gas puede entrar al aparato ya sea a través del piso o a través de la pared. El agujero para la línea de gas debe hacer

Page 30 - TABLA DE CONTENIDO

16942-3-0910Page 8Cuando esté de frente al aparato los siguientes espacios libres mínimos a la construcción combustible deben mantenerse.Lado izquier

Page 31 - ADVERTENCIA

16942-3-0910 Page 9TECHOPAREDLATERALANTEPECHO VENTANA O REPISA24”MIN(610mm)14” MIN(356mm)6” MIN(152mm)6” MIN(152mm)PISO2” MIN(51mm)Cuando esté de fren

Page 32 - PUNTOS PARA RECORDAR

16942-3-0910Page 10Cuando esté de frente al aparato los siguientes espacios libres mínimos a la construcción combustible deben mantenerse.Lado izquie

Page 33 - ESPECIFICACIONES

16942-3-0910 Page 11Figura 11 (SR-18)Figura 12 (SR-30)En Pared Maciza 1. Después de ubicar los oricios del montaje, adjunte (4) tornil-los #10 x 1&

Page 34

16942-9-0314Page 4Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must nd out if you can smell

Page 35

16942-3-0910Page 12 1. Alinear los oricios de la base con los oricios de los tornil-los en la parte inferior del calentador, como se muestra en la

Page 36 - ANTEPECHO VENTANA O REPISA

16942-3-0910 Page 131. ¡ALTO! Lea la información de seguridad arriba mencionada.2. Apagar todo el sistema eléctrico del calentador (si fuera pertin

Page 37

16942-3-0910Page 14SR-6 La Flama del Quemador (Figura 15) La ama del quemador tendrá un color rojo - anaranjado resplandiente sobre lîPsup

Page 38

16942-3-0910 Page 152. Aplicar aire a presión a través de los oricios del piloto indicados por las echas. Esto soplará materiales extraños, tales c

Page 39

16942-3-0910Page 16Para Remover el Piloto/Termopar Del Ensamblaje Principal del QuemadorAtención: El termopar NO PUEDE cambiarse por si sólo. Ud. debe

Page 40 - Figura 14

16942-3-0910 Page 17INDEX PARTNUMBER NUMBER DESCRIPTIONINDEX PARTNUMBER NUMBER DESCRIPTION 1 13344 Gabinete Latereal Izquierdo 2 R-

Page 41 - INSTRUCCIONES DE ENCENDIDO

16942-3-0910Page 18 USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.INDEX PARTNUMBER NUMBER

Page 42 - INCORRECTO

16942-3-0910 Page 19SR-6 — VISTA DE PARTES

Page 43

16942-3-0910Page 20SR-10 — VISTA DE PARTES

Page 44 - MANTENIMIENTO DEL APARATO

16942-3-0910 Page 21SR-18 — VISTA DE PARTES

Page 45 - COMO PEDIR PARTES DE REPUESTO

16942-9-0314 Page 5Instructions to Installer1. Installer must leave instruction manual with owner after installation.2. Installer must have owner ll

Page 46

16942-3-0910Page 22SR-30 — VISTA DE PARTES

Page 47 - SR-6 — VISTA DE PARTES

16942-3-0910 Page 23INTERRUPTOR ON/OFCABLE ENTRADA ENGABINET TRASEROPROTECTORCALORTORNILLO ALAMBRE TIERRAREFLECTOR Y PERSIANAS SEDEMONTAN DEL GABINETE

Page 48 - SR-10 — VISTA DE PARTES

16942-3-0910Page 24CablesEl aparato debe estar conectado a tierra de acuerdo al “National Electrical Code” ANSI/NFPA 70. Este Ventilador viene equipa

Page 49 - SR-18 — VISTA DE PARTES

16942-3-0910 Page 25NOTAS DE SERVICIO

Page 50 - SR-30 — VISTA DE PARTES

16942-3-0910Page 26NOTAS DE SERVICIO

Page 51 - SRB-18 y SRB-30 para

16942-3-0910 Page 27NOTAS DE SERVICIO

Page 52

16942-3-0910Page 28Empire Comfort Systems Inc. garantiza que este producto de calefacción ambiental se encuentra libre de defectos al momento de la co

Page 53 - NOTAS DE SERVICIO

16942-9-0314Page 6Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for ever

Page 54

16942-9-0314 Page 7The gas line can be routed either through the oor or wall. The gas line opening should be made at this time. Location of the openi

Page 55

16942-9-0314Page 8Figure 3 (SR-6)When facing the front of the appliance the following minimum clearances to combustible construction must be maintaine

Page 56

16942-9-0314 Page 9Figure 5 (SR-10)CEILINGWINDOW SILL OR SHELF24” MIN(610mm)14” MIN(356mm)12” MAX(305mm)0” (0mm) CLEARANCETO REAR WALLSIDE VIEW2” MIN(